Multi Core, XLPE Insulated, Wire/ Tape Armored, PVC Sheathed Cable (N2XRY , N2XBY )

Attributes
No. & nominal Cross Section of the conductors
(mm²)
NominaI Insulation Thickness
(mm)
Filler Thickness(mm)steel Wire Diameter(mm)Nominal Sheath Thickness
(mm)
Average Outer Diameter (mm)Maximum conductor Resistance at 20℃
(Ω / Km)
Approx. weight
(Kg / Km)
2×1.50.710.91.813.712.1329
2×2.50.710.91.814.57.41378
2×40.710.91.815.54.61449
2×60.710.91.816.93.08550
2×100.711.251.819.41.83793
2×160.711.251.821.41.151010
2×250.911.61.825.30.7271477
2×350.911.61.827.70.5241830
3×1.50.710.91.814.212.1362
3×2.50.710.91.8157.41419
3×40.710.91.816.14.61505
3×60.710.91.817.63.08626
3×100.711.251.820.31.83918
3×160.711.251.822.41.151197
3×250.911.61.826.50.7271763
3×350.911.61.829.20.5242207
4×1.50.710.91.81512.1410
4×2.50.710.91.815.97.41477
4×40.710.91.817.14.61580
4×60.711.251.819.53.08823
4×100.711.251.821.71.831086
4×160.711.61.824.81.151550
4×250.911.61.828.60.7272115
4×350.911.61.931.80.5242694
5×1.50.710.91.815.812.1459
5×2.50.710.91.816.97.41546
5×40.711.251.818.94.61756
5×60.711.251.820.83.08955
5×100.711.251.823.31.831267
5×160.711.61.826.71.151825
5×250.911.61.8310.7272488
5×350.911.61.934.40.5243194
6×1.5110.91.816.812.1485
7×1.5110.91.816.812.1505
10×1.510.41.251.820.512.1760
12×1.51.0.41.251.82112.1816
14×1.510.41.251.821.712.1885
16×1.510.41.251.822.612.1956
19×1510.41.251.823.512.11047
21×1.510.41.61.825.212.11256
24×1.510.41.61.827.212.11406
30×1.510.41.61.828.412.11573
37×1.510.41.61.830.212.11800
6×2.510.41.251.818.77.41663
7×2.511.251.251.818.77.41692
10×2.511.251.251.822.17.41912
12 × 2.50.71.2511.822.67.41986
14 × 2.50.71.2511.823.57.411076
16 × 2.50.71.611.825.27.411303
19 × 2.50.71.611.826.27.411435
21 × 2.50.71.611.827.37.411540
24×2.50.71.611.829.67.411737
30×2.50.71.611.931.27.411977
37×2.50.71.611.933.27.412271
Description

Technical Data

  • Power and control cables, XLPE insulated, wire or tape armored, PVC sheathed for energy supply and control applications.

Nominal voltage Uo / U

  • 0.6/1kV

Main standard

  • IEC 60502 - 1

Cable code

  • N2XRY
  • N2XBY

Temperature range

  • - 40 to+ 90 °C

Cable Layer Construction

  • Cu /XLPE / Bd / SWA/ PVC
  • Cu/ XLPE / Bd / DTA/ PVC

Cable Structure

  • Conductor material: Bare copper conductor according to IEC 60228, class 1 ( solid ), class 2 ( stranded ) or class 5 ( flexible )
  • XLPE core insulation: Cross linked polyethylene compound
  • Core insulation colors: As per customer request
  • PVC inner covering.
  • Armour: Galvanized steel wire or tape.
  • PVC outer sheath: Compound type of PVC/ ST2.
  • Sheath color is normally black.
  • These Types of cables can also be manufactured with aluminium or aluminium alloy conductors, according to IEC 60228

Application

These types of cables are used for distribution of electrical energy supply and control applications for fixed installations in underground, cable ducts, indoors, in water and open air where more mechanical protection isrequired.

In addition, XLPE insulation material has better mechanical, electrical, chemical and durability characteristics than PVC