Extra Flexible, Flat, PVC Sheathed Cables
(H05VVH2 – F , H05VVH6 – F , H07VVH2 – F , H07VVH6 – F)
No. & Nominal Cross Section of Conductors (mm²) | Nominal Insulation Thickness (mm) | Nominal Sheath Nominal Sheath e₁ (mm) | Nominal Sheath Nominal Sheath e₂ (mm) | Nominal Sheath Nominal Sheath e₃ (mm) | Average Outer Dimension Width (mm) | Average Outer Dimension Thickness (mm) | Max. Conductor Resistance at 20 °c ( Ω / Km ) | Approx. Weight (Kg / Km) |
---|---|---|---|---|---|---|---|---|
3×0.75 | 0.6 | 1 | 0.9 | 1.5 | 10.2 | 4.3 | 26 | 65 |
3×1 | 0.6 | 1 | 0.9 | 1.5 | 10.8 | 4.5 | 19.5 | 80 |
3×1.5 | 0.7 | 1 | 1 | 1.5 | 10.7 | 5 | 13.3 | 97 |
3×2.5 | 0.8 | 1.5 | 1 | 1.8 | 13.5 | 5.6 | 7.98 | 154 |
4×0.75 | 0.6 | 1 | 0.9 | 1.5 | 12.6 | 4.3 | 26 | 90 |
4×1 | 0.6 | 1 | 0.9 | 1.5 | 13.4 | 4.5 | 19.5 | 104 |
4×1.5 | 0.7 | 1 | 1 | 1.5 | 13.7 | 5 | 13.3 | 133 |
4×2.5 | 0.8 | 1.5 | 1 | 1.8 | 17 | 5.6 | 7.98 | 205 |
4×4 | 0.8 | 1.5 | 1.2 | 1.8 | 21.8 | 7 | 4.95 | 344 |
4×6 | 0.8 | 1.5 | 1.2 | 1.8 | 24.8 | 8.2 | 3.3 | 424 |
4×10 | 1 | 1.5 | 1.4 | 1.8 | 29.6 | 10 | 1.91 | 710 |
4×16 | 1 | 1.5 | 1.5 | 2 | 34.4 | 11.2 | 1.21 | 1015 |
4×25 | 1.2 | 1.5 | 1.6 | 2 | 42.6 | 13.7 | 0.78 | 1365 |
5×0.75 | 0.6 | 1 | 0.9 | 1.5 | 16.1 | 4.3 | 26 | 115 |
5×1 | 0.6 | 1 | 0.9 | 1.5 | 16 | 4.5 | 19.5 | 134 |
5×1.5 | 0.7 | 1 | 1 | 1.5 | 17.9 | 2 | 13.3 | 169 |
5×2.5 | 0.8 | 1.5 | 1 | 1.8 | 21.5 | 5.6 | 7.98 | 256 |
5×4 | 0.8 | 1.5 | 1.2 | 1.8 | 27.4 | 7 | 4.95 | 428 |
5×6 | 0.8 | 1.5 | 1.2 | 1.8 | 31.8 | 8.2 | 3.3 | 530 |
5×10 | 1 | 1.5 | 1.4 | 1.8 | 35.6 | 10 | 1.91 | 840 |
5×16 | 1 | 1.5 | 1.5 | 2 | 46.6 | 11.2 | 1.21 | 1350 |
5×25 | 1.2 | 1.5 | 1.6 | 2 | 55.5 | 13.7 | 0.78 | 1970 |
6×0.75 | 0.6 | 1 | 0.9 | 1.5 | 19.4 | 4.3 | 26 | 141 |
6×1 | 0.6 | 1 | 0.9 | 1.5 | 20.6 | 4.5 | 19.5 | 161 |
6×1.5 | 0.7 | 1 | 1 | 1.5 | 20.5 | 5 | 13.3 | 205 |
6×2.5 | 0.8 | 1.5 | 1 | 1.8 | 25.1 | 5.6 | 7.98 | 440 |
9×0.75 | 0.6 | 1 | 0.9 | 1.5 | 26.4 | 4.3 | 26 | 198 |
9×1 | 0.6 | 1 | 0.9 | 1.5 | 28.4 | 4.5 | 19.5 | 230 |
9×1.5 | 0.7 | 1 | 1 | 1.5 | 23.5 | 5 | 13.3 | 301 |
9×2.5 | 0.8 | 1.5 | 1 | 1.8 | 32.3 | 5.6 | 7.98 | 510 |
12×0.75 | 0.6 | 1 | 0.9 | 1.5 | 33.8 | 4.3 | 26 | 258 |
12×1 | 0.6 | 1 | 0.9 | 1.5 | 36.2 | 4.5 | 19.5 | 298 |
12×1.5 | 0.7 | 1 | 1 | 1.5 | 28.9 | 5 | 13.3 | 421 |
12×2.5 | 0.8 | 1.5 | 1 | 1.8 | 47.1 | 5.6 | 7.98 | 580 |
16×0.75 | 0.6 | 1 | 0.9 | 1.5 | 44.4 | 4.3 | 26 | 340 |
16×1 | 0.6 | 1 | 0.9 | 1.5 | 47.6 | 4.5 | 19.5 | 395 |
18×0.75 | 0.6 | 1 | 0.9 | 1.5 | 49.2 | 4.3 | 26 | 380 |
18×1 | 0.6 | 1 | 0.9 | 1.5 | 52.8 | 4.5 | 19.5 | 441 |
20×0.75 | 0.6 | 1 | 0.9 | 1.5 | 55 | 4.3 | 26 | 424 |
20×1 | 0.6 | 1 | 0.9 | 1.5 | 59 | 4.5 | 19.5 | 495 |
24×0.75 | 0.6 | 1 | 0.9 | 1.5 | 65.6 | 4.3 | 26 | 509 |
24×1 | 0.6 | 1 | 0.9 | 1.5 | 70.4 | 4.5 | 19.5 | 590 |
e1: The nominal space between each group of wires.
e2: Sheath thickness at the top and the bottom.
e3: Sheath thickness at the edges.
Technical Data
- Extra flexible flat cables, PVC insulated, PVC sheathed.
Nominal voltage Uo / U
- 300/500V for conductors up to and including 1 mm².
- 450/750V for conductors above 1mm²
Reference Standard
- IEC 60227-6
Cable code
- 60227 IEC 71 F
- H05VVH2-F
- H05VVH6-F
- H07VVH2-F
- H07VVH6-F
Temperature range
- Animated installation: +5℃ to +70℃
- Fixed installation: -30℃ to +70℃
Cable Layer Construction
- Cu/PVC/PVC
Cable Structure
- Conductor material: Flexible copper conductor according to IEC 60228, class 5.
- PVC core insulation: Compound type of PVC/ D.
- Cores lay parallel.
- Core insulation colors: Up to 5 cores, color or number coding and for more than 5 cores, number coded imprints. The green / yellow earth core is the last core.
- PVC outer sheath: Compound type of PVC / ST5For more flexibility we can apply TPR* ( TPE** ) for insulation and / or sheathing.
*TPR: Thermo Plastic Rubber
**TPE: Thermo Plastic Elastomer - Sheath color is black or gray.
Application
These types of cables are mainly used as trailing cables for crane installations, floor conveyor systems, shelf
control units, hoist equipments, transport installations and as a lead in for moving machine parts.
These cables are suitable for indoor use and their advantages are:
– Extremely small bending radius.
– High flexibility.
– Minimum waste of space.
– Fitting in small packages.
بدون دیدگاه