Outdoor Unfilled Telephone Cables

A-2Y (St) 2Y



کابل های مخابراتی بیرون ساختمان
Attributes
Cable Size
(mm)
Nominal Insulation Thickness
(mm)
Nominal Sheath Thickness
(mm)
Nominal Outer Diameter
(mm)
Approx. Weight
(Kg/Km)
2×2×0.40.1814.226
4×2×0.40.181543
6×2×0.40.1815.650
8×2×0.40.1816.161
10×2×0.40.1816.673
2×2×0.60.2115.130
4×2×0.60.2116.447
6×2×0.60.2117.366
8×2×0.60.211.18.185
10×2×0.60.2118.8104
15×2×0.60.2119.8127
20×2×0.60.211.411.5171
25×2×0.60.211.412.5209
30×2×0.60.211.414253
40×2×0.60.211.215.7326
50×2×0.60.211.417.3399
70×2×0.60.211.420.4555
100×2×0.60.211.423.8771
2×2×0.80.315.841.2
4×2×0.80.317.469
6×2×0.80.318.596
10×2×0.80.31.210.7153
20×2×0.80.31.214.1280
30×2×0.80.31.216.7404
40×2×0.80.31.419.3538
50×2×0.80.31.421.2660
70×2×0.80.31.424.5902
100×2×0.80.31.629.11279
Description

Technical Data

  • Outdoor unfilled telephone cables, HDPE insulated, aluminium shielded and HDPE outer sheath with UV resistance.

 Peak working voltage

  • 225V (DC)

 Max.conductor resistance

  • for 0.4mm/Km :147Ω
  • for 0.5mm/Km :101Ω
  • for 0.6mm/Km :65Ω
  • for 0.8mm/Km :36.6Ω

Temperature range

  • −30 ℃ to +70 ℃

 Max. mutual capacitance

  • 52±4nf/Km

Reference standard

  • *TCI

TCI: Telecommunication Company of Iran

  • VDE 0816

Min. insulation resistance

  • 20,000MΩ.Km

Cable code

  • A-2Y (St) 2Y

Cable Layer Construction

  • Cu/HDPE/OSCR/HDPE

Cable Structure

  • Conductor material: Solid annealed conductor with smooth and uniform surface.
  • PE core insulation: Compound of type Ill, class B, category 4 or 5 and grade EB according to ASTM D - 1248
  • Core identification: The single cores are twisted together to form a pair; pairs are color coded and twisted pairs form the cable core.
  • Core wrapping: A layer of polyester film wrapped helically or longitudinally for core protection.
  • Aluminium shield: A layer of aluminium foil wrapped helically or longitudinally as a shield in contact with a single tinned copper wire.
  • PE outer sheath: Compound of type Ill, class B, category 4 or 5 and grade J3, according to ASTM D - 1248.
  • Sheath color is black

Application

All outdoor cables are principally suitable for installation in most types of plants.
Cables with an outer sheath of polyethylene without adequate protective measures should not be used in plants with fire explosion hazards.

None of these cables are suitable for power installation purposes and are mainly operated at low frequencies and only in the circuits. Also, they are used as primary and secondary cables in local telephone networks, as railway communication cables and in industrial plants.