Unscreened, Flexible, Control Cables
(H05VV – F , NYSLY )

 

کابل‌های کنترل افشان
Property
No. & Nominal
Cross Section of Conductors
(mm²)
Nominal Insulation Thicknes
(mm)
Nominal Sheath Thicknes
(mm)
Average Outer Diameter Min (mm)Average Outer Diameter Max (mm)Max. Conductor
Resistance
at 20 °C(Ω / Km)
Approx
Weight
(Kg / Km)
2×0.50.60.75.26.63942
2×0.750.60.85.77.22654
2×10.60.85.97.519.562
2×1.50.70.86.88.613.383
2×2.50.80.98.210.37.98124
3×0.50.60.75.573950
3×0.750.60.867.62664
3×10.60.86.3819.574
3×1.50.70.97.49.413.3104
3×2.50.81911.27.98155
4×0.50.60.86.27.93963
45×0.750.60.86.68.32677
4×10.60.86.98.719.590
4×1.50.70.98.210.213.3127
4×2.50.81.110.112.57.98195
5×0.50.60.86.88.63974
5×0.750.60.97.49.32694
5×10.60.97.89.819.5110
5×1.50.719.111.413.3155
5×2.50.81.11113.77.98232
6×0.50.60.97.69.63989
6×0.750.60.98.110.126109
6×10.618.710.819.5132
6×1.50.71.110.212.613.3184
6×2.50.81.212.215.17.98276
7×0.50.60.98.310.439102
7×0.750.61911.326130
7×10.619.511.819.5152
7×1.50.71.211.314.113.3219
7×2.50.81.313.616.87.98326
12×0.50.61.110.412.939153
12×0.750.61.11113.726186
12×10.61.211.814.619.5229
12×1.50.71.313.81713.3320
12×2.50.81.516.820.67.98489
18×0.50.61.212.315.339221
18×0.750.61.313.216.426282
18×10.61.31417.219.5332
18×1.50.71.516.520.313.3474
18×2.50.81.820.224.87.98731
27×0.50.61.415.118.639339
27×0.750.61.516.219.926431
27×10.61.5172119.5508
27×1.50.71.820.324.913.3732
27×2.50.82.124.730.27.981122
36×0.50.61.51720.939432
36×0.750.61.618.222.426550
36×10.61.719.423.819.5660
36×1.50.722328.213.3947
36×2.50.82.32834.27.981448
>Any number of conductors, up to 61 x 2.5 can be manufactured as per customer request.
Description

Cable Layer Construction

  • Cu/PVC/PVC

Cable Structure

  • Conductor material: Flexible copper conductor according to EC 60228, class 5.
  • PVC core insulation: Compound type of PVC/ D.
  • Core insulation colors: Up to 5 cores, color or number coding and for more than 5 cores number coded imprints. For 3 or more cores the green / yellow earth core is the last core in the outer layer.
  • PVC outer sheath: Compound type of PVC/ ST5 ** This type of PVC compound is not oil resistant.
  • Sheath color is normally black.

Application

These types of cables are used for flexible and medium mechanical stresses with free movement without tensile
stresses or forced movement in dry, moist and wet rooms. They are not suitable for open air, wherever internationally
recognized PVC cables are required such as control or measurement cables on industrial machinery, conveyor
systems or industrial plants.

Technical Data

  • Unscreened flexible control cables, PVC insulated, PVC sheathed.


Nominal Voltage Uo / U

  • 300/500V


Reference standard

  • IEC 60227-7


Cable code

  • 60227 IEC 75
  • H05VV-F
  • NYSLY


Temperature range

  • - 30℃ to + 70℃

بدون دیدگاه

Leave a Reply