Self Supporting Aerial Aluminium Cables

(A2X – T , ABC)

کابل های خودنگهدار آلومینیومی
Attributes

Low Voltage self Supporting Aerial Aluminium cables Three-Phase & Single- phase with neutral&aluminium alloy Messenger

Nominal Cross Section of Conductors (mm²)No. & Dia.of wires for phase (mm) Minimum Thickness of Insulation for phase (mm)No. & Dia.of wires for Lighting (mm)Minimum Thickness of Insulation for Lighting (mm)No. & Dia.of wires for Neutral & Messenger (mm)Minimum Thickness of Insulation Neutral & Messenger(mm)Cable Approximate Weight (kg/km)Maximum Resistance of Conductor at 20°C
3×35+16+50
7 × 2.6
1.6
7 × 1.72
1.2
7 × 3.15
1.6
684
0.868
3×50+16+50
7 × 3
1.6
7 × 1.72
1.2
7 × 3.15
1.6
803
0.641
3×70+16+70
19 × 2.2
1.8
7 × 1.72
1.2
7 × 3.61
1.6
1083
0.443
3 ×95 +25+70
19 × 2.6
1.8
7 × 2.2
1.2
7 × 3.61
1.6
1362
0.32
3×120+25+70
19 × 2.83
1.8
7 × 2.2
1.2
7 × 3.61
1.6
1575
0.253
1×16+16+35
7 × 1.72
1.2
7 × 1.72
1.2
7 × 2.54
1.6
278
1.91
1×25+16+35
7 × 2.2
1.4
7 × 1.72
1.2
7 × 2.54
1.6
314
1.2
1×35 +16+50
7 × 2.6
1.6
7 × 1.72
1.2
7 × 3.15
1.6
408
0.868
2 ×16
7 × 1.72
1.2
----131
1.91
2 ×25
7 × 2.2
1.4
----203
1.2

Low Voltage self Supporting Aerial Aluminium cables Three-phase & single- phase (Six wire)

Nominal Cross Section of Conductors (mm²)No. & Dia.of wires for phase (mm)Minimum Thickness of Insulation for phase (mm)No. & Dia.of wires for Neutral (mm)Minimum Thickness of
Insulation for Neutral(mm)
No. & Dia.of wires for Lighting (mm) Minimum Thickness of Insulation for Lighting (mm)No. & Dia.of wires for Messenger (mm)Minimum Thickness of
Insulation for Messenger (mm)
Cable Approximate Weight (kg/km)Maximum Resistance of Conductor at 20°C
3×25+25+16+167 × 2.2
1.4
7 × 2.2
1.4
7 × 1.72
1.2
7×1.57
1
568
1.2
3×35+35+25+25
7 × 2.6
1.6
7 × 2.6
1.6
7 × 2.2
1.4
7 ×1.93
1.1
806
0.868
3×50+50+25+25
7 × 3
1.6
7 × 3
1.6
7 × 2.2
1.4
7 ×1.93
1.1
964
0.641
3×70+70+25+25
19 × 2.2
1.8
19 × 2.2
1.8
7 × 2.2
1.4
7 ×1.93
1.1
1259
0.443
3×95+95+25+25


19 × 2.6
1.8
19 × 2.6
1.8
7 × 2.2
1.4
7 ×1.93
1.1
1619
0.32
3×120+120+25+25
19 × 2.83
1.8
19 × 2.83
1.8
7 × 2.2
1.4
7 ×1.93
1.1
1896
0.253
1×25+25+16+16
7 × 2.2
1.4
7 × 2.2
1.4
7 × 1.72
1.2
7×1.57
1397
1.2
1×35+35+16+25
7 × 2.6
1.6
7 × 2.6
1.6
7 × 1.72
1.2
7 ×1.93
1.1
469

0.868
1×16+16+16
7 × 1.72
1.2
7 × 1.72
1.6
--7×1.57
1262
0.641
1×25+25+16
7 × 2.2
1.4
7 × 2.2
1.8
--7×1.57
1329
0.443

Description

Technical Data

  • Self supporting aerial aluminium cables, XLPE insulated

Nominal Voltage

  • 0.6/1kV

Reference standard

  • BS 7870 - 5

Cable code

  • A2X – T
  • *ABCABC:Aerial Bundled Cables*

Temperature range

  • - 40 to + 90 °C

Cable Layer Construction

  • Al/XLPE
  • St/Al/XLPE
  • Al Alloy/XLPE

Cable Construction

  • Class & Material of Conductors:Material of Conductors For Phase, lighting & Neutral: Stranded (class2)-Compacted Aluminum according To IEC 60228 (ISIRI 3084).
    Material of Conductors For Neutral &Messenger: Stranded (class2)-Non Compacted Aluminum Alloy.
    Material of Conductors For Messenger: Stranded (class2)-Non Compacted steel.
  • Insulation Material : Cross linked Polyethylene (XLPE)
    Color Insulation: Black
  • Insulation Identification:.Phases 1 - 2 - 3: One - Two - Three Longitudinal Ribs Respectively.
    Lighting: Smooth &Without Longitudinal Ribs.
    Neutral: Evenly Spaced Longitudinal Ribs.
    Messenger: Smooth &Without Longitudinal Ribs

Application

These types of cables are used for overhead lines to supply energy. They have much better characteristics than hard drawn bare conductors.

بدون دیدگاه

Leave a Reply