Indoor Telephone Cables
J-2Y (St) Y
Cable Size (mm) | Nominal Insulation Thickness (mm) | Nominal Sheath Thickness (mm) | Nominal Outer Diameter (mm) | Approx. Weight (Kg/Km) |
---|---|---|---|---|
2×2×0.6 | 0.2 | 0.6 | 4.8 | 35 |
4×2×0.6 | 0.2 | 0.6 | 5.9 | 54 |
6×2×0.6 | 0.2 | 0.6 | 6.7 | 71 |
8×2×0.6 | 0.2 | 0.6 | 7.4 | 88 |
10×2×0.6 | 0.2 | 0.6 | 8 | 105 |
15×2×0.6 | 0.2 | 1 | 9.3 | 145 |
20×2×0.6 | 0.2 | 1 | 10.4 | 184 |
25×2×0.6 | 0.2 | 1.1 | 12 | 250 |
30×2×0.6 | 0.2 | 1.2 | 12.7 | 273 |
40×2×0.6 | 0.2 | 1.2 | 14.2 | 350 |
50×2×0.6 | 0.2 | 1.2 | 15.6 | 426 |
70×2×0.6 | 0.2 | 1.4 | 18.4 | 592 |
100×2×0.6 | 0.2 | 1.4 | 21.4 | 686 |
2×2×0.8 | 0.25 | 1 | 5.6 | 48 |
4×2×0.8 | 0.25 | 1 | 7 | 79 |
6×2×0.8 | 0.25 | 1 | 8 | 108 |
8×2×0.8 | 0.25 | 1 | 9 | 136 |
10×2×0.8 | 0.25 | 1 | 9.8 | 163 |
15×2×0.8 | 0.25 | 1.2 | 11.9 | 240 |
20×2×0.8 | 0.25 | 1.2 | 13.3 | 307 |
30×2×0.8 | 0.25 | 1.2 | 15.7 | 438 |
40×2×0.8 | 0.25 | 1.2 | 17.7 | 567 |
50×2×0.8 | 0.25 | 1.4 | 19.9 | 712 |
70×2×0.8 | 0.25 | 1.4 | 23 | 967 |
100×2×0.8 | 0.25 | 1.4 | 26.9 | 1129 |
Technical Data
- Indoor voice frequency telephone cables, PVC insulated, aluminium shielded and PVC outer sheath.
Peak Working Voltage
- 300V (DC)
Max. conductor resistance
- for 0.4mm/Km :147Ω
- for 0.5mm/Km :101Ω
- for 0.6mm/Km :65Ω
- for 0.8mm/Km :36.6Ω
Temperature Range
- −30 ℃ to +70 ℃
Max. mutual capacitance
- 52±4nf/Km
Min. insulation resistance
- 20,000MΩ.Km
Main Standard
- IEC 60189
- VDE 0816
Cable Code
- J-2Y (St) Y
Cable Layer Construction
- Cu/HDPE/OSCR/PVC
Cable Structure
- Conductor material: Solid annealed conductor with smooth and uniform surface.
- PE core insulation: Compound of type Ill, class B, category 4 or 5 and grade EB according to ASTM D - 1248
- Core identification: The single cores are twisted together to form a pair; pairs are color coded and twisted pairs form the cable core.
- Core wrapping: A layer of polyester film wrapped helically or longitudinally for core protection.
- Aluminium shield: A layer of aluminium foil wrapped helically or longitudinally as a shield in contact with a single bare or tinned copper wire.
- PVC outer sheath: Compound type of YM 1.
- Sheath color is gray
Application
These types of cables are used for transmission of analog or digital signals and also for fixed installations. In communications technology the following connections can be installed:
Telephone, Telefax,Telex as well as standard modems of postal services, alarm systems for burglary and fire, communications and paging systems, access control, time and data control systems.
بدون دیدگاه