Screened, Flexible, Control Cables
(H05VC4V – F , NYSLCY , NYSLYCY)
No. & Cross Section of Conductors (mm²) | Nominal Insulation Thickness (mm) | Nominal Inner Covering Thicknes (mm) | Nominal Diameter of Screen Conductor (mm) | Nominal Sheath Thickness (mm) | Average Outer min. (mm) | Average Outer max. (mm) | Max. Conductor Resistance at 20 °c ( Ω / Km ) | Approx. Weight (Kg / Km) |
---|---|---|---|---|---|---|---|---|
2×0.5 | 0.6 | 0.7 | 5.2 | 6.6 | 7.7 | 9.6 | 39 | 70 |
2×0.75 | 0.6 | 0.7 | 0.15 | 0.9 | 8 | 10 | 26 | 80 |
2×1 | 0.6 | 0.7 | 0.15 | 0.9 | 8.2 | 10.3 | 19.5 | 82 |
2×1.5 | 0.7 | 0.7 | 0.15 | 1 | 9.3 | 11.6 | 13.3 | 104 |
2×2.5 | 0.8 | 0.7 | 0.15 | 1.1 | 10.7 | 13.3 | 7.98 | 141 |
3×0.5 | 0.6 | 0.7 | 0.15 | 0.9 | 8 | 10 | 39 | 75 |
3×0.75 | 0.6 | 0.7 | 0.15 | 0.9 | 8.3 | 10.4 | 26 | 89 |
3×1 | 0.6 | 0.7 | 0.15 | 1 | 8.8 | 11 | 19.5 | 97 |
3×1.5 | 0.7 | 0.7 | 0.15 | 1 | 9.7 | 12.1 | 13.3 | 127 |
3×2.5 | 0.8 | 0.7 | 0.15 | 1.1 | 11.3 | 14 | 7.98 | 177 |
4×0.5 | 0.6 | 0.7 | 0.15 | 0.9 | 8.5 | 10.7 | 39 | 91 |
4×0.75 | 0.6 | 0.7 | 0.15 | 1 | 9.1 | 11.3 | 26 | 106 |
4×1 | 0.6 | 0.7 | 0.15 | 1 | 9.4 | 11.7 | 19.5 | 116 |
4×1.5 | 0.7 | 0.7 | 0.15 | 1.1 | 10.7 | 13.2 | 13.3 | 157 |
4×2.5 | 0.8 | 0.8 | 0.15 | 1.2 | 12.6 | 15.5 | 7.98 | 221 |
5×0.5 | 0.6 | 0.7 | 0.15 | 1 | 9.3 | 11.6 | 39 | 105 |
5×0.75 | 0.6 | 0.7 | 0.15 | 1 | 9.7 | 12.1 | 26 | 122 |
5×1 | 0.6 | 0.7 | 0.15 | 1.1 | 10.3 | 12.8 | 19.5 | 141 |
5×1.5 | 0.7 | 0.8 | 0.15 | 1.2 | 11.8 | 14.7 | 13.3 | 189 |
5×2.5 | 0.8 | 0.8 | 0.2 | 1.3 | 13.9 | 17.2 | 7.98 | 276 |
6×0.5 | 0.6 | 0.7 | 0.15 | 1 | 9.9 | 12.4 | 39 | 118 |
6×0.75 | 0.6 | 0.7 | 0.15 | 1.1 | 10.5 | 13.1 | 26 | 143 |
6×1 | 0.6 | 0.7 | 0.15 | 1.1 | 11 | 13.6 | 19.5 | 162 |
6×1.5 | 0.7 | 0.8 | 0.15 | 1.2 | 12.7 | 15.7 | 13.3 | 217 |
6×2.5 | 0.8 | 0.8 | 0.2 | 1.4 | 15.2 | 18.7 | 7.98 | 325 |
7×0.5 | 0.6 | 0.7 | 0.15 | 1.1 | 10.8 | 13.5 | 39 | 137 |
7×0.75 | 0.6 | 0.7 | 0.15 | 1.2 | 11.5 | 14.3 | 26 | 163 |
7×1 | 0.6 | 0.8 | 0.15 | 1.2 | 12.2 | 15.1 | 19.5 | 188 |
7×1.5 | 0.7 | 0.8 | 0.2 | 1.3 | 14.1 | 17.4 | 13.3 | 261 |
7×2.5 | 0.8 | 0.8 | 0.2 | 1.5 | 16.5 | 20.3 | 7.98 | 373 |
12×0.5 | 0.6 | 0.8 | 0.2 | 1.3 | 13.3 | 16.5 | 39 | 200 |
12×0.75 | 0.6 | 0.8 | 0.2 | 1.3 | 13.9 | 17.2 | 26 | 254 |
12×1 | 0.6 | 0.8 | 0.2 | 1.4 | 14.7 | 18.1 | 19.5 | 297 |
12×1.5 | 0.7 | 0.8 | 0.2 | 1.5 | 16.7 | 20.5 | 13.3 | 396 |
12×2.5 | 0.8 | 0.9 | 0.2 | 1.7 | 19.9 | 24.4 | 7.98 | 599 |
18×0.5 | 0.6 | 0.8 | 0.2 | 1.3 | 15.1 | 18.6 | 39 | 290 |
18×0.75 | 0.6 | 0.8 | 0.2 | 1.5 | 16.2 | 19.9 | 26 | 353 |
18×1 | 0.6 | 0.8 | 0.2 | 1.5 | 16.9 | 20.8 | 19.5 | 405 |
18×1.5 | 0.7 | 0.9 | 0.2 | 1.7 | 19.6 | 24.1 | 13.3 | 571 |
18×2.5 | 0.8 | 0.9 | 0.2 | 2 | 23.3 | 28.5 | 7.98 | 839 |
27×0.5 | 0.6 | 0.8 | 0.2 | 1.6 | 18 | 22.1 | 39 | 402 |
27×0.75 | 0.6 | 0.9 | 0.2 | 1.7 | 19.3 | 23.7 | 26 | 512 |
27×1 | 0.6 | 0.9 | 0.2 | 1.7 | 20.2 | 24.7 | 19.5 | 598 |
27×1.5 | 0.7 | 0.9 | 0.2 | 2 | 23.4 | 28.6 | 13.3 | 815 |
27×2.5 | 0.8 | 1 | 0.25 | 2.3 | 28.2 | 34.5 | 7.98 | 1203 |
36×0.5 | 0.6 | 0.9 | 0.2 | 1.7 | 20.1 | 24.7 | 39 | 521 |
36×0.75 | 0.6 | 0.9 | 0.2 | 1.8 | 21.3 | 26.2 | 26 | 653 |
36×1 | 0.6 | 0.9 | 0.2 | 1.9 | 22.5 | 27.6 | 19.5 | 753 |
36×1.5 | 0.7 | 1 | 0.25 | 2.2 | 26.6 | 32.5 | 13.3 | 1048 |
36×2.5 | 0.8 | 1.1 | 0.25 | 2.4 | 31.5 | 38.5 | 7.98 | 1587 |
Technical Data
- Flexible screened control cables, PVC insulated, PVC inner sheath, braided copper wire for electromagnetic protection, PVC sheathed.
Nominal voltage Uo / U
- 300/500V
Reference Standard
- IEC 60227-7
Cable code
- 60227 IEC 74
- H05VC4V-F
- NYSLCY
- NYSLYCY
Temperature range
- -30℃ to +70℃
Cable Layer Construction
- Cu/PVC/Bd/CWB/PVC
- Cu/PVC/PET/CWB/PVC
Cable Structure
- Conductor material: Flexible copper conductor according to IEC 60228, class 5.
- PVC core insulation: Compound type of PVC/ D.
- Core insulation colors: Up to 5 cores, color or number coding and for more than 5 cores, number coded imprints. For 3 or more cores, the green / yellow earth core is the last core in the outer layer.
- PVC inner covering: Compound type of PVC/ ST 5.( The inner covering can be substituted by a polyester film if customer requests )
- Screen : Braided copper or tinned copper wire.
- PVC outer sheath: Compound type of PVC/ ST5 ** This type of PVC compound is not oil resistant.
- Sheath color is normally gray.
Application
These types of cables are used as link and connection control cables for machine tools, conveyor belts and plant
production lines, measuring and automatic control, computer units, construction equipments, power stations, cooling
and data processing systems and office machines. They are mostly installed in dry, damp or wet rooms at normal
stresses.
The copper braid serves as electromagnetic screen between the internal electric circuits and the environment,
therefore, it would eliminate any effects of electrical noises in the system.
بدون دیدگاه