RG 59 + 2 × 0.35 mm²
Coaxial cable specifications
Cable Type Number and Nominal Conductor Diameter(mm) Conductor Material Nominal Insulation Thickness(mm) Nominal Insulation Diameter(mm)
Nominal Sheath Thickness(mm)
Nominal Outer Diameter(mm)
RG - 59 1×0.67 Cu 1.4 3.6 1 6.5
Power cable specifications
Number of Cores Number and Nominal Conductor Diameter(mm) Nominal Insulation
Thickness(mm)Nominal Sheath Thickness(mm) Nominal Outer Diameter(mm)
2 17x 0.145 0.6 0.8 5.5
Technical Data
- High frequency coaxial cables (RG-59) combined with a light multi-core power cable
Maximum Conductor Resistance:
- 48.09Ω/Km
Impedance:
- 75±3Ω
Cable code
- CCTV (B)
Temperature range
- - 30℃ to + 70℃
Cable Layers Construction
- (Cu/FPE/Al Foil/CWB/PVC) + (Cu/PVC/PVC)
Cable Structure
Coaxial Cable
- Conductor material: Plain copper according to IEC 60228 (ISIRI 3084), class 1 (Solid).
- Insulation Material: Foamed polyethylene.
- Shield 1: A layer of aluminum foil is wrapped longitudinally.
- Shield 2: Plain copper braid with 60% coverage.
- Outer Sheath material: PVC compound.
- Outer Sheath color: Black.
Power Cable
- Conductor material: Plain copper according to IEC 60228 (ISIRI 3084), class 5 (Flexible).
- Insulation Material: PVC compound
- Cores Identification: Black, Red
- Outer sheath material: Compound type of PVC / ST1.
- Outer sheath color: Black.
Application
This type of cable combines RG59 coaxial cable for recordings by the camera, and a power cable for the energy supply for electrical devices. Generally, these cables are used to monitor and control industrial locations, commercial buildings, airports, etc.