Off-Shore Instrumentation Cables

کابل های ابزار دقیق دریایی مسی ساده / شیلددار
Attributes
Nominal Cross Section of Conductors ( mm2 )Class of ConductorsMica Tape Thickness
(mm)
Nominal Insulation
Thickness
( mm )
Nominal. inner covering
Thickness ( mm )
Nominal Diameter of braid armor
( mm )
Nominal Sheath Thickness
( mm )
Nominal Outer Diameter
( mm )
Max. Conductor
Resistance at 20℃
(Ω/Km)
Approx. Weight (Kg/Km)
Cable structure:
Cu (TiCu) / XLPE / OSCR / LSZH
4×2×2.52-0.6--1.315.87.86357
Cable structure:
Cu (TiCu) / XLPE / ISCR / OSCR / LSZH
4×2×2.52-0.6--1.418.27.86437
Cable structure:
Cu (TiCu) / XLPE / Bd / CWB (TiCWB) / LSZH
4×2×2.52-0.610.31.418.77.86530
Cable structure:
Cu (TiCu) / XLPE / Bd / SWB / LSZH
4×2×2.52-0.610.31.418.77.86520
Cable structure:
Cu (TiCu) / XLPE / OSCR / Bd / CWB (TiCWB) / LSZH
4×2×2.52-0.610.31.419.27.86545
Cable structure:
Cu (TiCu) / XLPE / OSCR / Bd / SWB / LSZH
4×2×2.52-0.610.31.419.27.86527
Cable structure:
Cu (TiCu) / XLPE / ISCR / OSCR / Bd / CWB (TiCWB) / LSZH
4×2×2.52-0.610.31.5217.86620
Cable structure:
Cu (TiCu) / XLPE / ISCR / OSCR / Bd / SWB / LSZH
4×2×2.520.610.31.5217.86610
Cable structure:
Cu (TiCu) / MGT / XLPE / ISCR / OSCR / Bd / CWB (TiCWB) / LSZH
4×2×2.520.120.610.31.5267.86785
Cable structure:
Cu (TiCu) / MGT / XLPE / ISCR / OSCR / Bd / SWB / LSZH
4×2×2.520.120.610.31.5267.86760
Description

Technical Data

  • Off-shore Instrumentation cables with or without screen, Multi-core and Multi-pair, XLPE Insulated, LSZH Sheathed.

Nominal Voltage

  • 150/250V (300V)

Main Standards

  • IEC 60092-376
  • IEC 60092-360
  • IEC 60332-1,3
  • IEC 60754-1,2
  • IEC61034-1,2
  • IEC60331-21

Temperature Range

  • - 40℃ to + 90℃

Cable Layers Construction

  • Cu(TiCu)/XLPE/OSCR/LSZH
  • Cu(TiCu)/XLPE/ISCR/OSCR/LSZH
  • Cu(TiCu)/XLPE/Bd/CWB(TiCWB)/LSZH
  • Cu(TiCu)/XLPE/Bd/SWB/LSZH
  • Cu(TiCu)/XLPE/OSCR/Bd/CWB(TiCWB)/LSZH
  • Cu(TiCu)/XLPE/OSCR/Bd/SWB/LSZH
  • Cu(TiCu)/XLPE/ISCR/OSCR/Bd/CWB(TiCWB)/LSZH
  • Cu(TiCu)/XLPE/ISCR/OSCR/Bd/SWB/LSZH
  • Cu(TiCu)/MGT/XLPE/ISCR/OSCR/Bd/CWB(TiCWB)/LSZH
  • Cu(TiCu)/MGT/XLPE/ISCR/OSCR/Bd/SWB/LSZH

Cable Structure

  • Conductor material: Plain or tinned annealed copper according to the IEC 60228 (ISIRI 3084), class 2 (stranded) or class 5 (flexible).
  • Tape: Mica Tape. (if any)
  • Insulation material: XLPE compound.
  • Core Identification: colored with numbers
  • Twisting: Cores twisted in the form of a pair, triple and quad.
  • Individual Screen: If ordered, a layer of the polyester tape will be applied helically over the pairs, triple and quads, then a drain wire of tinned annealed copper (the same size as wire conductors), will be used alongside and they all will be wrapped helically by aluminum foil.
  • Overall screen: A layer of aluminum foil will be wrapped helically over the polyester tape using a drain wire of tinned annealed copper (the same size as wire conductors), under the foil.
  • Bedding Material: For armored cables, an extruded bedding compound, the same material as the outer sheathing is applied (if any)
  • Wire Braided Screen: Plain or tinned annealed copper (if any)
  • Braided Armor: Plain or tinned annealed copper or galvanized steel (if any)
  • Outer Sheath Material: Low Smoke/Halogen Free (LSZH) compound
  • Outer Sheath Color: according to the customer's request

Application

These types of cables are suitable for data transmission and can be used in ships/vessels and off-shore structures.

بدون دیدگاه

Leave a Reply